<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>hardware &#8211; 88 Proof Synth Bio Blog</title>
	<atom:link href="http://88proof.com/synthetic_biology/blog/archives/tag/hardware/feed" rel="self" type="application/rss+xml" />
	<link>http://88proof.com/synthetic_biology/blog</link>
	<description>Genetically Engineered Organisms, Systems Biology, and Synthetic Biology from an Engineer&#039;s Viewpoint</description>
	<lastBuildDate>Wed, 09 Dec 2009 01:45:15 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.4.2</generator>
	<item>
		<title>More on Bio-lab Automation &#8211; Software for Controlling FIAlab Devices for Microfluidics</title>
		<link>http://88proof.com/synthetic_biology/blog/archives/407</link>
					<comments>http://88proof.com/synthetic_biology/blog/archives/407#comments</comments>
		
		<dc:creator><![CDATA[JonathanCline]]></dc:creator>
		<pubDate>Sat, 10 Oct 2009 01:06:34 +0000</pubDate>
				<category><![CDATA[Bioinformatics]]></category>
		<category><![CDATA[Technical]]></category>
		<category><![CDATA[automation]]></category>
		<category><![CDATA[hardware]]></category>
		<category><![CDATA[lab equipment]]></category>
		<category><![CDATA[microfluidics]]></category>
		<category><![CDATA[Perl]]></category>
		<category><![CDATA[Software]]></category>
		<guid isPermaLink="false">http://88proof.com/synthetic_biology/blog/?p=407</guid>

					<description><![CDATA[Perl software to control lab syringe pump and valve device, for biology automation, initial version finished today. Works great.  Next, need to add the network code, it can be controlled remotely and in synchronization with other &#8230; <a class="more-link" href="http://88proof.com/synthetic_biology/blog/archives/407">More<span class="meta-nav">&#8594;</span></a>]]></description>
		
					<wfw:commentRss>http://88proof.com/synthetic_biology/blog/archives/407/feed</wfw:commentRss>
			<slash:comments>2</slash:comments>
		
		
			</item>
		<item>
		<title>&#8220;Centrifuge the column(s) at ≥10,000×g (13,000 rpm) for 1 minute, then discard the flow-through.&#8221;</title>
		<link>http://88proof.com/synthetic_biology/blog/archives/380</link>
		
		<dc:creator><![CDATA[JonathanCline]]></dc:creator>
		<pubDate>Thu, 30 Jul 2009 16:43:45 +0000</pubDate>
				<category><![CDATA[Notes]]></category>
		<category><![CDATA[Technical]]></category>
		<category><![CDATA[hardware]]></category>
		<category><![CDATA[lab equipment]]></category>
		<category><![CDATA[Skunkworks]]></category>
		<guid isPermaLink="false">http://88proof.com/synthetic_biology/blog/?p=380</guid>

					<description><![CDATA[A basic equation of physics, for those out there building their own centrifuges: What are RPM, RCF, and g force and how do I convert between them? The magnitude of the radial force generated in a &#8230; <a class="more-link" href="http://88proof.com/synthetic_biology/blog/archives/380">More<span class="meta-nav">&#8594;</span></a>]]></description>
		
		
		
			</item>
		<item>
		<title>Low Cost Microcontroller-based Digital Microfluidics using &#8220;Processing&#8221;</title>
		<link>http://88proof.com/synthetic_biology/blog/archives/338</link>
					<comments>http://88proof.com/synthetic_biology/blog/archives/338#comments</comments>
		
		<dc:creator><![CDATA[JonathanCline]]></dc:creator>
		<pubDate>Thu, 02 Jul 2009 03:49:04 +0000</pubDate>
				<category><![CDATA[Skunkworks]]></category>
		<category><![CDATA[Technical]]></category>
		<category><![CDATA[hardware]]></category>
		<category><![CDATA[microcontroller]]></category>
		<category><![CDATA[microfluidics]]></category>
		<category><![CDATA[Processing.org]]></category>
		<category><![CDATA[Software]]></category>
		<guid isPermaLink="false">http://88proof.com/synthetic_biology/blog/?p=338</guid>

					<description><![CDATA[I&#8217;ve now tested the digital microfluidics board via microcontroller. The digital microfluidics board moves a liquid droplet via Electrowetting-on-Dielectric (EWOD).  The microcontroller switches the high voltage via a switching board (pictured below, using Panasonic PhotoMOS chips), &#8230; <a class="more-link" href="http://88proof.com/synthetic_biology/blog/archives/338">More<span class="meta-nav">&#8594;</span></a>]]></description>
		
					<wfw:commentRss>http://88proof.com/synthetic_biology/blog/archives/338/feed</wfw:commentRss>
			<slash:comments>2</slash:comments>
		
		
			</item>
		<item>
		<title>HVPS for Systems Biology: A Low Cost, High Voltage Power Supply with Schematics + Board Layout</title>
		<link>http://88proof.com/synthetic_biology/blog/archives/303</link>
					<comments>http://88proof.com/synthetic_biology/blog/archives/303#comments</comments>
		
		<dc:creator><![CDATA[JonathanCline]]></dc:creator>
		<pubDate>Tue, 23 Jun 2009 00:19:20 +0000</pubDate>
				<category><![CDATA[Notes]]></category>
		<category><![CDATA[Skunkworks]]></category>
		<category><![CDATA[Technical]]></category>
		<category><![CDATA[diy]]></category>
		<category><![CDATA[hardware]]></category>
		<category><![CDATA[lab equipment]]></category>
		<category><![CDATA[microfluidics]]></category>
		<guid isPermaLink="false">http://88proof.com/synthetic_biology/blog/?p=303</guid>

					<description><![CDATA[I have designed this high voltage, low current power supply for various experiments in systems &#38; synthetic biology. I have cleaned up the design and I am placing the schematic and board layout online below!  This &#8230; <a class="more-link" href="http://88proof.com/synthetic_biology/blog/archives/303">More<span class="meta-nav">&#8594;</span></a>]]></description>
		
					<wfw:commentRss>http://88proof.com/synthetic_biology/blog/archives/303/feed</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>DIY Digital Microfluidics for Automating Biology Protocols (sub-microliter droplets)</title>
		<link>http://88proof.com/synthetic_biology/blog/archives/280</link>
					<comments>http://88proof.com/synthetic_biology/blog/archives/280#comments</comments>
		
		<dc:creator><![CDATA[JonathanCline]]></dc:creator>
		<pubDate>Wed, 03 Jun 2009 15:56:25 +0000</pubDate>
				<category><![CDATA[Notes]]></category>
		<category><![CDATA[Skunkworks]]></category>
		<category><![CDATA[diy]]></category>
		<category><![CDATA[hardware]]></category>
		<category><![CDATA[microfluidics]]></category>
		<guid isPermaLink="false">http://88proof.com/synthetic_biology/blog/?p=280</guid>

					<description><![CDATA[Systems biologists and synthetic biologists spend a large amount of time moving small liquids from one vial to another. I would say it makes up the majority of their work day, even in a technologically cutting-edge &#8230; <a class="more-link" href="http://88proof.com/synthetic_biology/blog/archives/280">More<span class="meta-nav">&#8594;</span></a>]]></description>
		
					<wfw:commentRss>http://88proof.com/synthetic_biology/blog/archives/280/feed</wfw:commentRss>
			<slash:comments>5</slash:comments>
		
		
			</item>
	</channel>
</rss>
